Poseidon devices matrix overview - remote monitoring devices over IP & SMS. Poseidon is system for data-center temperature and environment monitoring. The Poseidon solution monitors (temperature, humidity, electricity supply, access to the room, water leak detector). Alerting works by e-mail, SNMP traps, SMS, output relays. |
| Poseidon: | 2250 | 3265 | 3266 | 3268 | 3468 | 4001 | 4002 |
| Model description | Poseidon 2250 | Poseidon 3265 | Poseidon 3266 | Poseidon 3268 | Poseidon 3468 | Poseidon 4001 | Poseidon 4002 |
| Model photo | 1 2 3 4 5 |
1 2 3 4 |
1 2 3 4 5 6 7 |
1 2 3 4 |
1 2 |
1 |
1 2 3 |
| Online demos | |||||||
| Digital Inputs | 3 DI | - | 4 DI | 4 DI | 4 DI | 6 DI | 6 DI |
| Door contact, Flood (water level) detector, Smoke and gas detectors, Voltage detector, Motion detector | |||||||
| Digital Outputs | 2 (RS-232) |
- | 2 DO (relay) |
2 DO (relay 110/230V) |
2+2 DO (relay + SwingHandle) |
2 DO (relay) |
|
| Swing Handle | - | - | - | - | - | 2 | - |
| 1-Wire sensors RJ11 bus up to 60m |
10 sensors | 5 sensors | 5 sensors | 5 sensors | 4 sensors | 16 sensors | 12 sensors |
| Temperature, Humidity | |||||||
| 1-Wire UNI support* | |||||||
| Voltage 0-15V / 0-60V, Current 0-20mA / 4-20mA / 0-30A AC | |||||||
| Industrial sensors RS-485 bus up to 1000m |
26 sensors | - | - | - | - | - | - |
| Temperature, Humidity, Air preassure, Voltage, Current | |||||||
| Power | 12V | 12V | 12V | 12V | 12V | 12V + 2x 48V + PoE | 12V |
| Logger capacity | 40 000 records | - | - | - | - | - | - |
| HTML, XML, Flash setup | |||||||
| Modbus/TCP | |||||||
| SNMP, SNMP Traps | |||||||
| SMTP Email | |||||||
| Alarms SMS (SMS GW) (Local / Remote GSM modem) |
|||||||
| SDK (Software Development Kit) | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Sensor overview (New products catalogue) |
>> |
>> |
>> |
>> |
>> |
>> |
|
| SDK (Software Development Kit) | |||||||
| Documentation | Flyer Manual Poseidon Manual |
Flyer Starting Guide Poseidon Manual |
Flyer Starting Guide Poseidon Manual |
Flyer Starting Guide Poseidon Manual |
Flyer Poseidon Manual |
Flyer Manual Poseidon Manual |
Flyer Manual Poseidon Manual |
| Firmwares | Firmware v.1.0.7 | Firmware v.3.1.3 |
Firmware v.3.1.7G
3.1.12 with DHCP |
Firmware v.3.1.6 | Firmware v.1.0.2 | Firmware v.2.0.8 | Firmware v.2.0.10 |
| Configuration SW | UDP Config | ||||||
| Application SW | PD Trigger, HWg-PDMS, CapTemp | ||||||
| Third party SW applications | Nagios, Zabbix, HP (OpenView) NNM, IBM Tivoli, MSC Operations Manager, The Dude, Paessler IPCheck, Ipswitch WhatsUp, Axence, LoriotPro, GFi NSM, SNMPc 7, CA NSM, ActiveXperts NM, Intellipool NM, ATEAS, AlViS | ||||||
| * Check the power limitation how many sensors can be connected per one RJ12 port (typically max 2 1-Wire UNI sensor per one port) | |||||||
Sensors, Probes & Detectors
Accessories
Keywords