Temp-232
A simple digital thermal sensor, communicating over RS-232 interface by a simple text protocol. Does not require power supply, the sensor is powered from PC's serial port.
The
measured temperature is sent directly in °C by a simple text protocol.
The sensor sends the measured value regularly (in predefined interval) or as a respond to a request
according to a specific Question-Answer protocol.
The thermal sensor uses an integrated element with
accuracy of ± 0,5°C for temperature measuring. LED indicates that temperature measuring is in progress.
.
Application
- Temperature measuring systems
- Industrial measuring and regulation
- Temperature measuring in warehouses, production and residential premises
- After connection to Poseidon - measuring in technological premises and transferring data via Ethernet
Basic properties
- The sensor is connected to PC over standard RS-232
- Temperature measuring in range from -55°C to +125°C
- The sensor address and a period of automatic temperature reporting can be set in terminal SETUP mode
- It can operate in Question-Answer mode
- LED indication of measuring
- Simple communication protocol
- Does not require power supply, powered directly from PC serial port
- The sensor cooperates with SNMP thermometer Poseidon
Downloads & Datasheets
Technical specifications
| Basic parameters |
+ Range of measured temperature |
-55°C to +125°C |
| + Resolution format |
0,1 °C |
| + Measurement accuracy |
+/- 0,5 °C in range from -10°C to +85°C
+/- 2 °C in range from -55°C to +125°C |
| Communication |
| + Measuring speed |
Respond to query within 50ms at maximum, measuring itself 1x within a second |
| + Measuring element |
DS18B20 |
| + Data format |
ASCII, described in specification |
| + Communication parameters |
9600 8N1 |
| + Communication line |
RS-232 (RxD, TxD, GND, DTR, RTS) |
| + Status indication |
Red indicator blinks at every measuring, ligths constantly in Terminal Setup mode |
| + Function modes |
Auto-Report / Question-Answer |
| - Auto-Report mode |
Temperature reported automatically in defined time,
period 1 .. 255 [seconds] |
| - Question-Answer |
Temperature reported on request according to protocol (request by a "t" character) |
| + Temperature format |
„+028.0C<CR><LF>“ |
| + Access to SETUP mode |
Sends „u“ (117 DEC) character 20x after turning on |
| + Turning on thermometer |
Setting DTR or RTS to „On“ value |

Sensor installation:
- Connect Temp-232 to PC port
- Run terminal program, choose serial port where the Temp-232 is connected, set speed to
9600, port parameters 8N1,
RTS and DTR output to „ON“
- In the terminal a temperature value will start to appear (in 2 second interval, preset in factory)
SETUP Terminal mode
- Turn on the thermometer (Set DTR or RTS to „On“ =
+12V)
- Access the SETUP mode by sending cca 20 „u“ (117 DEC) characters after turning on.
You can just hold the "u" key until the LED of the thermometer lights up.
- Choose parameters in Setup mode using the first letters of the desired command
|
DB9F on the cable  |
| 1 |
- |
- |
Not used |
| 2 |
TxD |
<-- |
Transmit Data |
| 3 |
RxD |
--> |
Receive Data |
| 4 |
PWR |
--> |
PWR input (from the DTR output) |
| 5 |
GND |
--- |
System Ground |
| 6 |
- |
- |
Not used |
| 7 |
PWR |
--- |
PWR input (from the RTS output) |
| 8 |
- |
- |
Not used |
| 9 |
- |
- |
Not used |
|
Ordering
Sensor samples are already available! We recommend ordering a standard "600
051 Temp-232 1.5m" version. Products
are in stock in several pieces most of the time. The price can be found
on the Pricelist page.
| OID |
Temp-232 type detailed description |
600 051
|
Temp-232 1.5m
Temperature sensor encased in black covering (preferred
type), cannon DB9M, sensor on 1.5 m cable. |
| 600 052 |
Temp-232 052
Temperature sensor encased in a brass 8mm thread, 50mm long |
| 600 053 |
Temp-232 053
Sensor encased in a brass 50mm long shape with 8mm thread, assembled
on DB9 cover (without cable). |
Similar products
- Damocles family
Poseidon family
Poseidon connects sensors of digital inputs, thermal, humidity and other sensors to Ethernet.
To one unit it's possible to connect up to 40 sensors. Immediate values are accestible over
WWW interface or XML, SNMP, Modbus/TCP.
- Eth. I/O Controller
Connection of binary inputs and outputs over Ethernet along with a serial line.
Binary states can be just remotely monitored (I/O Controller in the Server mode),
or the device itself notifies of a change on the input pins (Client/Server mode).
|