EZL-50 and EZL-60 - Ethernet converter - RS-232/TTL

The EZL-50 is an embedded RS-232 (TTL) converter for Ethernet data transmission via 10Base-T. TCP connection can be controlled by AT commands from a serial port as standard modems telephone lines. EZL-60 is a development kit for the EZL-50.

 

  • EZL-50 - Embedded module for a conversion of a serial TTL signal to an Ethernet network data signal.
  • EZL-60 - Development kit with the EZL-50 module assembled in connectors, the RS-232 port and the RJ45 connector for direct connection to the Ethernet network.

 

The EZL-50 Module

EZL-50 module is an embedded converter of an Ethernet interface to the RS-232C (TTL) supporting UDP/IP and TCP/IP. Connection to the Ethernet standard 10Base-T (network with UTP cables) needs using the external signal transformer and then TP RJ45 connector itself (transformer is supplied on request with the module).

EZL-50 is intended for conversion of a serial data signal in TTL (5V) voltage level and is suitable for direct connection to the serial line of controll MCU and CPU. Speciality of this product is an ATC mode in which the configuration change can be achieved by a simple sequence of the AT commands of the connected microcontroller. Your application can therefore treat the module as a classic telephone modem (open a TCP connection on an IP address, send data, receive amswer, shut the TCP connection, connect to other IP addres..).

The EZL-60 development kit

The EZL-60 is a development kit for the EZL-50 module. It contains EZL-50 module inserted in the bottom panel. Development kit contains a classic 9-pin connector for RS-232 (DB9M), a RJ-45 connector for a UTP cable,a feeding connector and other necessary peripheries. By switching the jumper on the development kit it is possible to upload individual FirmWares into the module over the serial port.

The EZL-60 development kit allows immediate module testing and its programming via RS-232 or Ethernet network before installation into a specific device. There are fastening slots bore in the printed circuit of the kit so it can be screwed to any device.

EZL - 50 module

EZL-50 module (detail)

 

EZL - 60 module

EZL-60 Kit (detail)

Properties

EZL - 50 :

  • Ethernet Network ( 10Base - T) - Ethernet interface (external signal regulator required)
  • One 5V UART/TLL serial port accessible via Ethernet (RxD, TxD, RTS, CTS)
  • Virtual serial port (ezVSP) for Windows - in PC as for example serial port COM 7 
  • Devices together can wirelessly connect the serial port over the Ethernet LAN network.
  • Several different Firmwares uploadable via serial port
    • TCP/IP (TCP Client or TCP Server)
    • TCP/IP - AT commands
    • UDP/IP
  • Special P0 pin which signalizes opened TCP connection
  • Intuitive and simple configuration software for Windows (Ethernet, RS-232, AT commands), very easy installation
  • Power supply by an external DC 5V power supply unit.
  • Development kit ( EZL-60 ) available.

 

EZL- 60 :

  • Slot for the EZL-50 module
  • RS-232 9-pin Female D-SUB connector with LED indication
  • Ethernet RJ-45 connector for UTP cable with LED indication
  • ISP jumper for programming mode
  • Coaxial feeding connector for 5V DC with a switch

Description of the EZL-60 kit (detail)

 

Datasheets & Links

 

Katalogový list k EZL-50 (1 strana]
EZL-50 datasheet
Podrobný manuál k EZL-50 (28 stran)
EZL-50 manual
Katalogový list k EZL-60 (1 strana)
EZL-60 datasheet
Podrobný manuál k EZL-60 (7 stran)
EZL-60 manual

 

Application


The embedded EZL-50 converter is connected to the device communicating via serial TTL (5V level) transmission. The EZL-60 module is already connected to the device communicating via serial RS-232 transmission.

Opposite side is represented by the Ethernet device or HUB, switch or router, which makes the serial port accessible to the Ethernet network and can be communicated from any PC connected to the network or Internet.

  • Remote communication of many sensors (e.g. electronic thermometers) and PC via LAN.
  • Remote monitor system
  • Traffic and information systems (displays)
  • Monitor and medical systems in a health service
  • Data transmission for information projection on displays.
  • Remote data retrieving of the MAR system (Measuring and Regulation).
  • Ethernet realization of factory networks with connection to LAN and Internet.
  • Security systems
  • Remote controlling of factory machines
  • Communication and connection of measuring devices (multimeters, oscilloscopes and others) via Ethernet network.

 

Parameters of the EZL-50

Serial port  
+ Data bits 7 or 8
+ Parity None / Odd / Even
+ Baud rates 1.2 .. 230.4 kBd - whole range (full duplex).
+ Data flow control CTS/RTS, None (SW handshake not supported)
+ Interface TTL, 5V level
EZL-50: 2mm pin header - male (RxD,TxD,RTS,CTS,GND)
+ Used RS-232 signals RxD,TxD,RTS,CTS
- RTS and CTS pins controlled by module FW, activation required
 
Ethernet port  
+ Interface Ethernet TP, external signal transformer required
+ Compatibility IEEE 802.3 Ethernet LAN 10Base-T
+ Supported protocols TCP, UDP, IP, ICMP, ARP, DHCP, TELNET,TFTP
+ TCP connection closing Data - timeout (optional)
+ TCP connection signalization P0 pin LOW when TCP connection opened
 
Environmental conditions  
+ Operating temperature 0– 70 °C
 
Physical parameters  
+ Voltage requirements 5V DC
+ Dimensions 50x 32x 9[mm] (H x W x D )
+ Weight 10g
 
Functional parameters  
Device SETUP configuration possibilities  - over any serial and RS-232 - AT commands
 - over Ethernet - ezConfig Windows software
 - firmware download over Ethernet (TFTP) - hotflash Windows software
LED diagnostic LINK & Activity on serial and Ethernet
- only signals are in the connector of EZL - 50

 

Parametry EZL-60

Serial port  
+ Interface 9-pin D-SUB Male (RxD,TxD,RTS,CTS,GND)
DTR-DST loopback on the board
 
Ethernet port  
+ Interface Connector RJ-45 (for UTP cabel)
 
Environmental conditions  
+ Operating temperature 0– 70 °C
 
Physical parameters  
+ Voltage requirements 5V DC - barrel (coaxial) power connector
+ Dimensions 100x 55x 21[mm] (H x W x D )
+ Weight cca 50g
 
Functional parameters  
Switches  - ISP Jumper (run Ethernet / FirmWare programming)
 - Reset switch
 - Power switch
LED diagnostic LINK & Activity on serial and Ethernet
- only signals are in the connector of EZL - 50

 

EZL - 50 - rozložení signálů na pinech:

 

Ethernet communication  modes :

Converter can behave as a client/server device according to chosen MUX TYPE (function modes):

 

Communication mode Protocol Connection Type  
T2S TCP Passive = TCP Server Converter listens on the selected port and awaits client's connection which can thereafter send or receive data
ATC TCP TCP Client / TCP Server Communication is controlled by transmitting AT commands over serial line which allows setting of the client/server mode (COD, T2S).
COD TCP Active = TCP Client Converter establishes connection when RS-232 port receives the data and allows transmission.
U2S UDP Point-to-Point / Broadcast Defined TCP port awaits data and sends them to IP address without a transmission control. This allows using a broadcast.
T2S, ATC, COD and U2S are the names of the individual FirmWares for the module. To change the mode it is necessary to upload specific FirmWare into the module via serial port.

 

Other supported communication protocols : ARP, EZCFG, DHCP, TELNET, TFTP

Experiences

ezVSP (Virtual Serial Port) program:

  • Instalation of this program is conditioned by ownership of at least one module.
  • During installation it's necessary to enter the MAC address of the module and a key which is obtained by a registration on Sollae webpage. Further installation description can be found in the program manual.

 

Configuration with ezConfig:

  • To establish a connection between the configuration program and the module this module must be connected to the Ethernet network.
  • By choosing a MAC address of the module the connection will be established.
  • The program can set parameters of both ethernet and serial port.

 

General:

  • The connection of the module's serial port and the application must be performed by so called "zero mode" principle. That means connection of the RxD - TxD and RTS - CTS pins from the view of both ends of the connecting cable..

 

Package

 

Download software

  • ezConfig softwareezConfig - for module configuration from PC via LAN and WiFi.
    Allows setting parameters for Ethernet and serial transmision.
    ezcfg24.zip (85kB)
  • hotflash - for loading firmware over Ethernet (TFTP)
  • hotflash.zip (97kB)

  • ezTerm softwareezTerm - for testing communication (terminal for PC)
    ezterm.zip (69kB)
  • ez Virtual Serial Port softwareezVSP - Virtual Serial Port for Windows - creates on the PC a virtual serial port (e.g. COM 7) which can be referenced by other programs and communicated as with the RS-232 interface even though the data transfer is actually via TCP/IP.
    Note: Program is intended for Windows 2000/XP only!
    ezVSP14a.zip (4,3MB)

Note: All programs (except ezVSP) work under OS Windows 98 and higher

 

Comparison of the Charon I and the EZL-50

What is the difference between the EZL-50 and the module known in Czech Republic - Charon I? Essentialy the EZL-50 is similar product which differs only in these parameters:

  • Charon I supports SW handshake, EZL-50 does not.
  • Charon I contains another 8 TTL I/O pins that can be controlled over Ethernet, EZL-50 has no such pins.
  • EZL-50 can signalize open TCP connection on the P0 pin, Charon I cannot.
  • For each mode of the EZL-50 its necessary to upload specific FW, Charon I supports all in one firmware which is configured in the setup mode.
  • EZL-50 supports AT Command mode, Charon I has nothing like that.
  • Charon I supports detailed definition of the begining and the end data which are to be send from serial line into the Ethernet, EZL-50 does not.
  • Charon I supports at once hendshaking on the external driver of the RS-485 line and the Half Duplex mode necessary for conversion to RS-485. EZL-50 does not support this.
  • EZL-50 uses connector with a RM of 2mm , Charon I uses standard 2,54 mm RM

 

Frequently Asked Questions & support..

Questions and information

Do you have any questions concerning this product? Are you interested in similar products or job order development? Then fill in the following form and we will respond as soon as possible.

Spam protection. How many is five times six?

Firm: 
Name: 
Email: 
Phone: 

  

Street: 
City: 
ZIP: 
Country: 


Notice :

Question: What is the difference between versions 50 and 60?
Answer: The EZL-50 version represents only the embedded module which can be installed into the printed circuit of your device by the means of a 2x12-pin interface. Besides the slot for the EZL-50 the EZL-60 version also contains classic 9-pin RS-232 connector and an RJ-45 ethernet connector for a UTP cable. The EZL-60 kit can be immediately and simply connected into the network and used.

Question: Would the serial port of the module work as a Virtual Serial Port under Windows?
Answer: YES, the converter fully supports the function of remote Virtual Serial Port through TCP/IP. Moreover the producer offers free program ezVSP to download. It's only necessary to register and enter the MAC address of the module you've bought.

Question:  Is it necessary to program the module some way if I only need a simple GateWay from RS-232 (TTL) to TCP/IP or UDP/IP?
Answer: NO, you only need to use the module and set necessary parameters. If you don't want to use a default Firmware for a TCP server it's necessary to upload new FW into the module via RS-232. You don't have to program anything!

Question: Is it possible to configure the module by other means than through Windows programs?
Answer: YES, by the means of AT commands through serial port and any terminal. The sequence of ASCII chars as AT commands can be thus transmitted even from singlechip microcontroller. The list of usable AT commands with examples of correct configuration sequences contains a detailed manual for the specific module.

Question:  Is it possible to change a FirmWare in the module?
Answer:  Yes it is, innovated FirmWares can be downloaded from the Sollae's webpage (www.ezTCP.com) and load into the module via Ethernet by the means of the program hotflash.

Question:  Does the ezVSP (Virtual Serial Port) software allow creating more than one virtual port?
Answer:  Yes, this software allows to set up to 127 virtual ports on one PC. Detailed guide on this can be found in the program's manual which is free to download on this page in the menu item "Datasheets".

Related

More Sollae Ethernet converters:

  • EZL-200 - complete encased converter with a LED indication and power supply

 
  Main page Products Support & Download Pricelist Contacts SiteMap  


HW group - Prague - Czech republic - Europe