Index >> Products HWg Supervision / Monitoring Products
Poseidon product line
Sensors
Poseidon product line
Environment monitoring – temperature, humidity, flood, entry of people, smoke, airflow, and more. Critical values and other information is transmitted over a network.
The Poseidon unit connects to the Ethernet, the power supply, and the sensors. Sensor readings are accessible over the Web as well as via other network protocols (SNMP, XML, SMTP, and so on).
Individual Poseidon models differ by the range of features, supported sensors, etc.
For more information: Poseidon product line / Poseidon XXXX
Poseidon accessories
Poseidon software
Sensors
Temperature
Temp-1Wire
- Accuracy: ±0.5°C, max total length 10m
- Interface: IT bus (Poseidon)
- Construction: Sensor on a 1m / 3m / 10m cable, connector: RJ12
Temp-1Wire – Outdoor
- Accuracy: ±0.5°C
- Interface: IT bus (Poseidon)
- Construction: Sensor in a stainless-steel casing on a 3m cable, connector: RJ12
- Temp-485
- Accuracy: ±0.5°C
- Interface: Industrial bus (RS485) – max total length 1000m, connector: RJ45 / terminal block
- Construction: Wall mount – external sensor
HTemp-485
- Accuracy: ±0.5°C temperature / ± 4% RH humidity
- Interface: Industrial bus (RS485) – max total length 1000m, connector: RJ45 / terminal block
- Construction: Wall mount – external sensor
Temp-485-Pt100 Box
- Accuracy: ±0.15°C
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: IP67 wall mount – external sensor
Temp-Rack19
- Accuracy: ±0.5°C
- Interface: IT bus (Poseidon)
- Construction: 2x RJ12 connector, 19" rack mount
- Converters for the Pt100 temperature sensor
Temp-485-Pt100 Cable
- Accuracy: ±0.2°C – outdoor sensor
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: Wall mount converter, temperature sensor on a 2m cable
Temp-485-Pt100 Head
- Accuracy: ±0.2°C
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: Converter fits into a B type head
- Temp-485-Pt100 DIN
- Accuracy: ±0.2°C
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: Converter to mount on a DIN rail
Temp-485-2xPt100
- Accuracy: 2x ±0.2°C
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: Converter to mount on a DIN rail, two external Pt100 sensors
- Temp-232
- Accuracy: ±0.5°C, max total length 20m
- Interface: RS-232
- Construction: Sensor on a 1.5m cable, connector: DB9F
Humidity
HTemp-485
- Accuracy: ±0.5°C temperature / ±4% RH humidity
- Interface: Industrial bus (RS485) – max total length 1000m, connector: RJ45 / 4-pin terminal block
- Construction: Wall mount – external sensor
Humid-1Wire
- Accuracy: ±4% RH, max total length 10m
- Interface: IT bus (Poseidon)
- Construction: Sensor on a 1m / 3m / 10m cable, connector: RJ12
HTemp-Rack19
- Accuracy: ±0.5°C temperature / ±4% RH humidity
- Interface: IT bus (Poseidon)
- Construction: 2x RJ12 connector, 19" rack mount
Flood (water level) detectors
Smoke and gas detectors
Voltage and current sensors
PowerEgg
110 to 230VAC mains voltage detector and controller with electrical isolation. Inputs and outputs are low-voltage contacts.
Sens-UI
Converts electrically isolated analog voltage (0 to 15V) and current (0 to 25 mA) signals at two inputs to a RS-485 line. Fits on a DIN rail.
- Interface: Industrial bus (RS485) – max total length 1000m, connector: terminal block
- Construction: Converter to mount on a DIN rail
Motion and position detectors
Accessories
|